Carbon figures for Drupflare and the hosts it is compared with.

Carbon is energy multiplied by a grid factor. The factor here is 384 g per kWh, the US average in Ember's Global Electricity Review 2025 [13]. Neither system controls the grid factor. The figures are derived by bun scripts/economics/fleet.ts, from the energy totals on Energy and Fleet Energy. The first tables are for one site against the production baseline, the later ones for the fleet.

With E the annual energy in kWh, G the grid factor in g per kWh and the result in kg CO2e a year:

\text{CO}_2\text{e} = \frac{E \cdot G}{1000}

Energy and carbon per site per year, derived:

deployment energy (a year) CO2e (kg a year)
production 224 kWh 86.1
peak-sized production 390 kWh 150
worst case, one small VPS 9.34 kWh 3.59
drupflare, 1M views a month 18.3 Wh 0.00701

Moving one site from peak-sized production to drupflare at a million views a month avoids 390 kWh and 150 kg of CO2e a year, derived.

The production row is the latency-matched shape in scripts/economics/energy.ts: three regions of four nodes, each node 4 vCPUs at 15% utilisation. Peak-sized production is the same three regions and four nodes at 8 vCPUs and 10% utilisation. The worst case is one 2 vCPU VPS sharing a 640-thread host at 15%, the case that leaves drupflare the smallest saving. The drupflare row is drupflareKwhYearOnMix at one million views a month, from scripts/economics/perview.ts. A host draws 135 W idle and 711 W at full load, interpolated linearly by utilisation, with the colocation PUE of 1.54 over 8,766 hours a year. The rows come from the last block of bun scripts/economics/fleet.ts, printed as "per site, per year, derived".

CO2e avoided per year by the fleet comparison, 1,000 sites against shared hosting, derived:

views/site/month CO2e avoided per year, 1,000 sites
10,000 701 kg
100,000 712 kg
1,000,000 800 kg
20,000,000 1,429 kg
100,000,000 1,876 kg
1,000,000,000 3,975 kg

These figures use the fleet model's quoted arm, the one with the smallest saving. Through 150 million views that is shared hosting charged the measured native costs, which are lower than drupflare's wasm costs, so the opponent's energy and the carbon avoided are lower than a drupflare-cost opponent would give. At 1 billion views the quoted arm is the same-cost one.

Each row is the quoted arm's shared-hosting energy minus drupflare's energy at that traffic, times the grid factor. bun scripts/economics/fleet.ts prints the rows under "carbon and water avoided per year, 1,000 sites". Its shared-hosting arms are described in scripts/economics/fleet.ts: the same-cost arm charges drupflare's own per-request CPU, and the two native arms charge the measured nginx and PHP-FPM costs.

A second accounting is less favourable. Charging drupflare its share of Cloudflare's entire published Scope 2 footprint [14] divided by every request the network serves [15] gives 24.6 micrograms of CO2e per request, which includes DNS and attack traffic a cached page has nothing to do with. Under that accounting, and charging three requests per page view, drupflare's attributed carbon crosses one site's share of shared hosting at about 792,000 views per month. Below that the saving is 87% to 99%. Above it the saving inverts.

bun scripts/economics/attributional.ts prints the per-request figure, the saving at 10,000, 100,000 and 1,000,000 views a month, and the crossover. bun scripts/economics/crossover.ts prints the crossover at one, two and three requests per view.

Choosing a Grid Factor

The US average is 384 g per kWh [13], and the EU's 2024 factor is 213 g per kWh [13]. At 213, the fleet CO2e figures above are 55% of their US values. Report energy first, and carbon with its factor named: two systems on the same regional grid can differ in kWh and barely differ in kg CO2e, or the reverse.